CollaborationOff in the current version
When you connect to Central gateway, you can exchange messages with colleagues and show a terminal screen read-only. The AI panel also uses this connection.
This chapter covers features that are switched off in the current version. They do not appear in the app; the text is kept for when they return.
Settings › GatewayOff in the current version
AI, Chat and terminal sharing can be used after you connect to Central gateway here. Get the address and token from your administrator.
URL
The gateway address you received from your administrator. The format is
ws://<host>:<port>.Token
The authentication token you received from your administrator. It is at least 16 characters long, and this is not the field for the address.
Connect on app start
Turn this on and Save to connect automatically when the app starts. It works only on a PC that has completed pairing.
Status
The current connection status. It is
Disconnectedat first.Test connection
Tests whether the address can be reached. On success, the Device pairing item appears.
Save
Saves URL, Token and Connect on app start and closes the dialog.
Device pairing and connectionOff in the current version
The first time only, you must register (pair) this PC with the gateway and get the administrator's approval. The figure is a screen made with sample values.
Press Test connection
Press it after entering URL and Token. When
WebSocket OKappears, the Device pairing item appears.Enter your operator ID in ID
The registered name has the form
<ID> @ <PC 이름>(ID @ PC name) and is used as the sender in Chat and the owner of a share.Press Request pairing
The status changes to
Pairing requested — waiting for admin approval.Wait for the administrator's approval
Approval is given by the gateway administrator, outside the app. Refresh reads the status again.
Press Connect
Press it after the status becomes
Paired — ready to connect. Once connected,Connectedand the Disconnect button appear.Turn on automatic connection (optional)
Turn on Connect on app start and Save; from then on the app connects automatically when it starts.
Status display and error messagesOff in the current version
The messages shown in Settings › Gateway and what to do for each.
| Display | Meaning | What to do |
|---|---|---|
Disconnected | Not connected | Start with Test connection. |
Testing… → WebSocket OK | The address can be reached. | Continue with Device pairing below. |
Failed: … | The address cannot be reached. | Check the address and the network. |
Check pairing status | The pairing status has not been read yet. | Press Check. |
Not paired | This PC is not registered. | Enter ID and press Request pairing. |
ID를 입력하세요 (Enter an ID) | ID is empty, so the request cannot be made. | Enter ID. |
Pairing requested — waiting for admin approval | Waiting for approval. | Tell the administrator and check with Refresh. |
Pairing repair required | The existing pairing token or permission does not match. | Press Repair pairing and get approval again. |
Paired — ready to connect | Approval is complete. | Press Connect. |
Connecting… / Reconnecting… | Connecting, or reconnecting after the connection dropped. | Wait. To stop, Disconnect. |
Connected | Connected. Device info below shows the first part of the token and the Collab relay status. | To disconnect, Disconnect. |
Connect failed: Gateway token is missing or invalid. … | Token is empty or has the wrong format. | Enter Token again. |
Chat panelOff in the current version
Opens when you press Chat on the Workspace toolbar of the Terminal view. The figure shows the state with no gateway connection.
Chat button
Opens and closes the panel. It is closed at first.
Relay status and your ID
The relay status line and your operator ID. If you have not set an ID, it is
operator.Rooms
Global, Current project, and a room named after the session (or group) you are viewing.
Messages
Sender, time and content. Up to the latest 120 messages per room are kept on the PC.
Input box and Send
Enterinserts a line break. A message is sent only when you press Send. There are no edit, delete or attachment features.
Relay status and delivery scopeOff in the current version
The Chat panel and the share dialog show the same status line. This line tells you whether messages and shares are delivered to other PCs.
| Category | Display | Meaning |
|---|---|---|
| Status | Gateway relay connected. Shares and operator chat now sync across paired laptops. | Messages and shares in all rooms are synchronized with other PCs. |
| Status | Gateway is connected. The app is preparing the collaboration relay connection. | Connected to the gateway and preparing the relay connection. |
| Status | Operator relay is not attached yet. You can still generate share keys and test the viewer locally on this desktop. | The relay is not connected. Messages and shares work only within this PC. |
| Rooms | Global | For all operators. Delivered when the gateway is connected. |
| Rooms | Current project | Scope of the current project. Delivered only while the relay is connected. |
| Rooms | Session name or group name | Scope of the session or group you are viewing. Delivered only while the relay is connected. |
Joining with ViewerOff in the current version
The person who received the share presses Viewer on the Workspace toolbar of the Terminal view and enters the secret key.
Enter does not open it.Things to know when sharingOff in the current version
Sharing passes on the text shown on the screen as it is. Know what is delivered and what records remain before you use it.
| Item | Details |
|---|---|
| What a viewer can do | Only read the screen text. There is no feature for typing or taking over control. |
| What is visible | Plain text with the colors removed. Up to the latest 60,000 characters per terminal are delivered. |
| Masking | None. Passwords, tokens and keys printed on the screen are delivered as they are. |
| Viewer restriction | The IDs entered in Viewer users are compared with the viewer's ID. An ID is the value each person types into ID under Settings › Gateway, and identity is not verified separately. |
| Transmission path | Delivered through the gateway. The app does not encrypt the content separately. |
| Ending | Press Stop. It stays in the list as Revoked, and there is no button to remove it from the list. |
| Validity period | The expiry time is recorded as 8 hours after creation. Whether the app disconnects automatically at that time was not verified. |
| Records left on the PC | Share records (including the secret key and the delivered screen text) remain in plain text in the app settings store. (chapter 17) |
Features that require a Gateway connectionOff in the current version
All the features below assume the connection in Settings › Gateway. Without a connection, the remaining features can still be used as they are.
| Feature | Where to open | What it does | Description |
|---|---|---|---|
| AI panel | AI on the Terminal Workspace toolbar | Server status questions and checks | chapter 13 |
| Chat | Chat on the Terminal Workspace toolbar | Messages between operators | this chapter |
| Terminal sharing | Share / Viewer on the Terminal Workspace toolbar | Shares a terminal screen read-only | this chapter |
| Project connection info sharing | Right-click a project in the Project sidebar › Share connection info / Import shared connection info | Passes saved connection settings to colleagues who use the same project | chapter 3 |
| Custom group structure sharing | Share tree / Import share in the Custom view of the Instances panel | Passes a group structure you created yourself (connection settings not included) | chapter 7 |